Short-circuit inductance measurements by ADC there was identified “Chapeau” type distribution of random error.

The determination of confidence interval of measurement random error of short-circuit inductance deviation ΔХs-c by algorithm (1.12–1.26) makes to increase the accuracy of the conducted measurements and the reliability of Smart Grid Monitoring System’s work for the control of short-circuit inductance of power transformers and the reactors.

Smart Grid Monitoring System makes it possible to continuously control the state of power transformer windings without their turning off from the network, to achieve their protection in the case of the appearance of the winding deformations or their damage, and it ensures the high accuracy of the inductance measurement with the confidence interval value of the random error less than +0,1 %. This increases the reliability of operation and the continuity of the power supply of the electrical energy users.

Active Vocabulary of electrotechnical terms and verbs:

Information-measuring system – информационно-измерительная система,

monitoring system – система мониторинга,

Smart Grid – интеллектуальная («умная») сеть,

inductance – индуктивность,

autotransformer – автотрансформатор,

short-circuit – короткое замыкание,

short-circuit testing – испытание на стойкость при коротком замыкании,

accuracy – точность,

accuracy of diagnostic parameters – точность (измерений) диагностических параметров,

confidence interval of measurement – доверительный интервал измерений,

Frequency Response Analysis – (метод) частотного анализа,

transformer winding fault diagnostic – диагностика повреждений обмоток трансформатора,

Low Voltage Impulse method – метод низковольтных импульсов,

short-circuit inductive reactance measurement – измерение индуктивного сопротивления короткого замыкания,

voltage transformer (TV) – трансформатор напряжения,

current transformer (CT) – трансформатор тока;

high-voltage circuit breaker (HVCB) – высокольтный выключатель,

dissolved gas analysis (DGA) – анализ растворённых (в масле) газов,

analog-to-digital converters (ADC) – аналого-цифровой преобразователь,

Short-current Testing Laboratory (STL) – лаборатория (стенд) испытаний на стойкость при коротком замыкании,

to enter- входить,

to include – включать (в себя),

to determine – определять,

to show – показывать,

to prevent – предотвращать.

Exercise 1. Match the English words and word-combinations given below with Russian evuivalents:

equipment a) получать,

application b) появление,

check c) непрерывный,

transformer d) применение,

windings e) оборудование,

Scheme f) среднее (значение),

to decrease g) трансформатор,

continuous h) определение,

measuring i) распределение,

converter j) среднеквадратичное отклонение,

primary k) значимая (величина),

voltage o) проверка,

calculation p) преобразователь,

Average q) случайная ошибка,

root-mean-square deviation r) первичный,

distribution s) схема,

short-circuit regime t) уменьшать,

determination u) напряжение,

appearance v) вычисление (расчёт)

random error x) режим короткого замыкания,

to obtain y) обмотка,

significant z) измеренный,

Exercise 2. Find the antonyms and translate them:

Appearance, increase, scientific, slow digital protection, high-voltage, necessary, automated working place, unscientific, rapid digital protection, nonautomated working place, unnecessary, decrease, low-voltage, disappearance.

Exercise 3. Study the Active vocabulary. Insert the missing verbs from the list into the sentence and translate them:

The five-year investment program __________ the construction of 73 new substations.